The wet electrostatic precipitator for flue gas treatment in a brick factory has been in operation for five years, with a decrease in dust removal efficiency. Inspection revealed that the causes were related to the discharge voltage of the electrode wires, electric field strength, and spraying of the wet electrostatic demister. Therefore, the titanium electrode wires, anti-sway frames, and nozzles were replaced.

On-site Replacement of Titanium Electrode Wires and Anti-sway Frames of Wet Electrostatic Demister for Flue Gas Treatment in a Brick Factory; Dust and Dirt Inside Are Clearly Visible
The flue gas treated by the wet electrostatic precipitator in the phosphating chemical industry is desulfurized flue gas mixed with water vapor. The flue gas contains highly corrosive media such as sulfur, phosphorus, arsenic, and fluorine, and the operating temperature is below 90 degrees Celsius.

The Removed Girders and Insulation Boxes of the Wet Electrostatic Precipitator with Severe Corrosion

The Removed Anode System and Air Chamber of the Wet Electrostatic Precipitator with Corrosion of Varying Degrees
Hebei Weimei's overhaul project of the wet electrostatic precipitator in a Yunnan sugar factory has been completed. Meeting environmental protection standards is an important part of the production line, and it is expected to play its due role in the upcoming sugar crushing season.

Overhaul Project of Wet Electrostatic Precipitator in a Sugar Factory

+86-18633235200